Introduction of HKUST Air Quality Research Supersite
Equipments Introduction
HKUST Air Quality Research Supersite Facility
 

Background

 

The supersite facility is located at the roof of the sea water pump house on the shorefront in the campus of The Hong Kong University of Science and Technology (HKUST). The facility faces Port Shelter and Sai Kung, which is a clean rural area with little residential and commercial development on the east coast of Sai Kung.

The HKUST Air Quality Research Supersite facility is partially supported by the Environment and Conservation Fund and the University Grants Council (through the Special Equipment Grant) of the HKSAR. The facility has a total floor area of 1232 m2. It includes a 10-m high automatic weather station, 9 plinths for outdoor samplers and facilities, and a weather-proof air-conditioned modular house of 72 m2 with 10 sample inlets for instrumentation.

This facility is now used for the first Hong Kong Air Quality Supersite Study, which focuses on real time characterization of ambient particulate matter. Gas and particle instruments are being installed to the site and measurements are expected to start in the spring of 2011. In addition, it is also being used for a number of air quality monitoring projects in collaboration with the
Hong Kong Environmental Protection Department (HKEPD).

Location of HKUST. HKUST is at the east coast of Hong Kong, facing Port Shelter and Sai Kung West Country Park. The South China Sea is farther away in the south and east. Digital map from Google.

 
 

HKUST Air Quality Research Supersite at the seafront facing Port Shelter in the east. There are no known significant anthropogenic sources nearby in Port Shelter. Digital image from Google.

Location of Supersite : Latitude : 22°20.272"N, Longitude : 114°16.049" E, Elevation : 14 m above sea-level
 

Floor plan of HKUST Air Quality Research Supersite. The supersite facility is composed of a fully air-conditioned modular house surrounded by 10 plinths (1 AWS tower + 9 samplers/equipments) on the side open to Port Shelter.

 
 

A Bird's eye view of HKUST Air Quality Research Supersite. The AWS tower is located at Plinth #1 on the left of the modular house while PM samplers are distributed on plinths open to Port Shelter.

 
 

The Air-conditioned Modular House. The AWS tower is on the left. Sample inlets for instruments (nominally 2 m above the checker plates) can be seen on the roof the house.

 
 
PM samplers installed at outdoor facing Port Shelter and Sai Kung West Country Park.
 
 
HKUST launches the first Air Quality Research Supersite to enhance air quality research, May 19, 2011
 
The Honorable Mr Edward Yau, Secretary for the Environment (6th from left), HKUST President Prof Tony F Chan (7th from left), senior members of the Environmental Protection Department, faculty members and vice presidents of The Hong Kong University of Science and Technology at the HKUST Air Quality Research Supersite.
 

Instrument

  

Outdoor equipment installed

 
Plinth No. Equipment PI
1 10-m AWS tower (Horizontal wind, Pressure, Rainfall, RH, Solar irradiance, Temperature) with Visibility Sensor (Model 6000, Belfort Instrument Company) Prof Alexis KH LAU
2 Micro-Orifice Uniform Deposition Impactor (MOUDI 110-NR) Prof Jian Z YU
3 SASS Air Sampler (SASS Speciation Sampler, Met ONE Instruments Inc.) Prof Jian Z YU
4 Sequential Air Sampler (Partisol-Plus 2025, Thermal Scientific) Prof Jian Z YU
5 Sequential Air Sampler (Partisol-Plus 2025, Thermal Scientific) Prof Jian Z YU
6 Sequential Air Sampler (Partisol-Plus 2025, Thermal Scientific) Prof Jian Z YU
7 Hi Vol Air Sampler (G1200-2.5, Andersen Instruments Inc.) Prof Jian Z YU
8 Hi Vol Air Sampler (G1200-2.5, Andersen Instruments Inc.) Prof Jian Z YU
9 SASS Air Sampler (SASS Speciation Sampler, Met ONE Instruments Inc.) Prof Jian Z YU
10 Hi Vol Air Sampler (G1200-2.5, Andersen Instruments Inc.) Prof Jian Z YU
Instrumentation installed inside the modular house
Sample Inlet Equipment PI
A POCP system (GC955-611 and GC955-811, Synspec BV) Prof Jian Z YU
B MARGA Ambient Air Analyzer (ADI 2080 1S, Metrohm AG) Prof Jian Z YU
C Synchronized Hybrid Ambient Real-time Particulate Monitor SHARP (5030, Thermo Scientific) Prof Jian Z YU
D Gas Analyzers System including SO2 (100A, API Inc.), NO/NO2/NOx (200E, Teledyne Instruments Inc.), CO (300A, API Inc.), O3 (400E, Teledyne Instruments Inc.) and CO2 (360E, Teledyne Instruments Inc.) Prof Alexis KH LAU and Dr NT LAU
E Nephelometer Prof Alexis KH LAU
F Real-Time Particle-Into-Liquid Iron Chromatography (PILS-IC, Metrohm AG) Prof Jian Z YU
G Real-Time EC/OC Analyzer (RT-4, Sunset Laboratory Inc.) Prof Jian Z YU
H Aethalometer Prof Alexis KH LAU
I Real-Time VOC Analyzer (AIRSENSE, V&F Analyse- und Messtechnik GmbH) Prof Arthur PS LAU
J High-resolution Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne Research Inc.) Prof Chak K CHAN
Cloud Condensation Nuclei Counter (CCN-200, Droplet Measurement Technologies Inc.) Prof Chak K CHAN
Humidified Tandem Differential Mobility Analyzer (2000C, Brechtel Manufacturing Inc.) Prof Chak K CHAN
Fast Mobility Particle Sizer Spectrometer (3091 FMPS, TSI Inc.) Dr NT LAU
Sky Window Micro Pulse Lidar (MPL-4B-532, Sigma Space Corporation) Prof Alexis KH LAU
 

Contacts

 

For further information on the supersite project, please contact

 

Supersite Project Manager:
Prof. Chak K Chan
Head and Professor, Division of Environment
Professor, Department of Chemical and Biomolecular Engineering
The Hong Kong University of Science and Technology
Clear Water Bay, Hong Kong, China
Tel: (852) 2358 7124
Email: keckchan@ust.hk

Site Manager:
Dr. NT Lau
Division of Environment
The Hong Kong University of Science and Technology
Clear Water Bay, Hong Kong, China
Tel: (852) 2358 6935
Email: ntlau@ust.hk

Last update: Nov 13, 2012